<efrbr:recordSet xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:efrbr="http://vfrbr.info/efrbr/1.1" xmlns:efrbr-work="http://vfrbr.info/efrbr/1.1/work" xmlns:efrbr-expression="http://vfrbr.info/efrbr/1.1/expression" xmlns:efrbr-manifestation="http://vfrbr.info/efrbr/1.1/manifestation" xmlns:efrbr-person="http://vfrbr.info/efrbr/1.1/person" xmlns:efrbr-corporateBody="http://vfrbr.info/efrbr/1.1/corporateBody" xmlns:efrbr-concept="http://vfrbr.info/efrbr/1.1/concept" xmlns:efrbr-structure="http://vfrbr.info/efrbr/1.1/structure" xmlns:efrbr-responsible="http://vfrbr.info/efrbr/1.1/responsible" xmlns:efrbr-subject="http://vfrbr.info/efrbr/1.1/subject" xmlns:efrbr-other="http://vfrbr.info/efrbr/1.1/other" xsi:schemaLocation="http://vfrbr.info/efrbr/1.1 http://vfrbr.info/schemas/1.1/efrbr.xsd"><efrbr:entities><efrbr-work:work identifier="http://purl.tuc.gr/dl/dias/7D221573-B997-438A-8B2D-3FBE3D929A23"><efrbr-work:titleOfTheWork>A simple maximum power point tracker for thermoelectric generators</efrbr-work:titleOfTheWork></efrbr-work:work><efrbr-expression:expression identifier="http://purl.tuc.gr/dl/dias/7D221573-B997-438A-8B2D-3FBE3D929A23"><efrbr-expression:titleOfTheExpression>A simple maximum power point tracker for thermoelectric generators</efrbr-expression:titleOfTheExpression><efrbr-expression:formOfExpression vocabulary="DIAS:TYPES">
            Peer-Reviewed Journal Publication
            Δημοσίευση σε Περιοδικό με Κριτές
         </efrbr-expression:formOfExpression><efrbr-expression:dateOfExpression type="issued">2018-10-25</efrbr-expression:dateOfExpression><efrbr-expression:dateOfExpression type="published">2016</efrbr-expression:dateOfExpression><efrbr-expression:languageOfExpression vocabulary="iso639-1">en</efrbr-expression:languageOfExpression><efrbr-expression:summarizationOfContent>ThermoElectric Generators (TEGs) are capable to harvest the ambient thermal energy for power-supplying sensors, actuators, biomedical devices etc. in the μW up to several hundreds of Watts range. In this paper, a Maximum Power Point Tracking (MPPT) method for TEG elements is proposed, which is based on controlling a power converter such that it operates on a pre-programmed locus of operating points close to the MPPs of the power-voltage curves of the TEG power source. Compared to the past-proposed MPPT methods for TEGs, the technique presented in this paper has the advantage of operational and design simplicity. Thus, its implementation using off-the-shelf microelectronic components with low-power consumption characteristics is enabled, without being required to employ specialized integrated circuits or signal processing units of high development cost. Experimental results are presented, which demonstrate that for MPP power levels of the TEG source in the range of 1-17 mW, the average deviation of the power produced by the proposed system from the MPP power of the TEG source is 1.87%. </efrbr-expression:summarizationOfContent><efrbr-expression:useRestrictionsOnTheExpression type="creative-commons">http://creativecommons.org/licenses/by/4.0/</efrbr-expression:useRestrictionsOnTheExpression><efrbr-expression:note type="journal name">Energy Conversion and Management</efrbr-expression:note><efrbr-expression:note type="journal volume">108</efrbr-expression:note><efrbr-expression:note type="page range">355-365</efrbr-expression:note></efrbr-expression:expression><efrbr-person:person identifier="http://users.isc.tuc.gr/~aparaskeyas"><efrbr-person:nameOfPerson vocabulary="TUC:LDAP">
            Paraskevas Alexandros
            Παρασκευας Αλεξανδρος
         </efrbr-person:nameOfPerson></efrbr-person:person><efrbr-person:person identifier="http://users.isc.tuc.gr/~ekoutroulis"><efrbr-person:nameOfPerson vocabulary="TUC:LDAP">
            Koutroulis Eftychios
            Κουτρουλης Ευτυχιος
         </efrbr-person:nameOfPerson></efrbr-person:person><efrbr-corporateBody:corporateBody identifier="http://www.elsevier.com/"><efrbr-corporateBody:nameOfTheCorporateBody vocabulary="S/R:PUBLISHERS">
            Elsevier
         </efrbr-corporateBody:nameOfTheCorporateBody></efrbr-corporateBody:corporateBody><efrbr-concept:concept identifier="F7AB9930-5511-4F15-B40F-5429C5FF46A9"><efrbr-concept:termForTheConcept>
            Boost converter
         </efrbr-concept:termForTheConcept></efrbr-concept:concept><efrbr-concept:concept identifier="0A4B0912-E6D8-4455-ACA9-5F193C70E3A4"><efrbr-concept:termForTheConcept>
            Energy harvesting
         </efrbr-concept:termForTheConcept></efrbr-concept:concept><efrbr-concept:concept identifier="285EAB3E-2373-43F8-BA68-153088208029"><efrbr-concept:termForTheConcept>
            Maximum power point tracking
         </efrbr-concept:termForTheConcept></efrbr-concept:concept><efrbr-concept:concept identifier="C5167E37-12E1-40E9-BC0D-804FF772DEE4"><efrbr-concept:termForTheConcept>
            Thermoelectric generator
         </efrbr-concept:termForTheConcept></efrbr-concept:concept></efrbr:entities><efrbr:relationships><efrbr-structure:structureRelations><efrbr-structure:realizedThrough sourceEntity="work" sourceURI="http://purl.tuc.gr/dl/dias/7D221573-B997-438A-8B2D-3FBE3D929A23" targetEntity="expression" targetURI="http://purl.tuc.gr/dl/dias/7D221573-B997-438A-8B2D-3FBE3D929A23"/></efrbr-structure:structureRelations><efrbr-responsible:responsibleRelations><efrbr-responsible:createdBy sourceEntity="work" sourceURI="http://purl.tuc.gr/dl/dias/7D221573-B997-438A-8B2D-3FBE3D929A23" targetEntity="person" targetURI="http://users.isc.tuc.gr/~aparaskeyas"/><efrbr-responsible:realizedBy sourceEntity="expression" sourceURI="http://purl.tuc.gr/dl/dias/7D221573-B997-438A-8B2D-3FBE3D929A23" targetEntity="person" targetURI="http://users.isc.tuc.gr/~aparaskeyas" role="author"/><efrbr-responsible:realizedBy sourceEntity="expression" sourceURI="http://purl.tuc.gr/dl/dias/7D221573-B997-438A-8B2D-3FBE3D929A23" targetEntity="person" targetURI="http://users.isc.tuc.gr/~ekoutroulis" role="author"/><efrbr-responsible:realizedBy sourceEntity="expression" sourceURI="http://purl.tuc.gr/dl/dias/7D221573-B997-438A-8B2D-3FBE3D929A23" targetEntity="person" targetURI="http://www.elsevier.com/" role="publisher"/></efrbr-responsible:responsibleRelations><efrbr-subject:subjectRelations><efrbr-subject:hasSubject sourceEntity="work" sourceURI="http://purl.tuc.gr/dl/dias/7D221573-B997-438A-8B2D-3FBE3D929A23" targetEntity="concept" targetURI="F7AB9930-5511-4F15-B40F-5429C5FF46A9"/><efrbr-subject:hasSubject sourceEntity="work" sourceURI="http://purl.tuc.gr/dl/dias/7D221573-B997-438A-8B2D-3FBE3D929A23" targetEntity="concept" targetURI="0A4B0912-E6D8-4455-ACA9-5F193C70E3A4"/><efrbr-subject:hasSubject sourceEntity="work" sourceURI="http://purl.tuc.gr/dl/dias/7D221573-B997-438A-8B2D-3FBE3D929A23" targetEntity="concept" targetURI="285EAB3E-2373-43F8-BA68-153088208029"/><efrbr-subject:hasSubject sourceEntity="work" sourceURI="http://purl.tuc.gr/dl/dias/7D221573-B997-438A-8B2D-3FBE3D929A23" targetEntity="concept" targetURI="C5167E37-12E1-40E9-BC0D-804FF772DEE4"/></efrbr-subject:subjectRelations><efrbr-other:otherRelations/></efrbr:relationships></efrbr:recordSet>