Institutional Repository [SANDBOX]
Technical University of Crete
EN  |  EL

Search

Browse

My Space

Quantification of trace transformation products of rocket fuel unsymmetrical dimethylhydrazine in sand using vacuum-assisted headspace solid-phase microextraction

Zhakupbekova Aray, Baimatova Nassiba, Psyllaki Eleftheria, Kenessov Bulat

Simple record


URIhttp://purl.tuc.gr/dl/dias/52A06935-1370-4283-9BE7-4CB36CAC349F-
Identifierhttps://doi.org/10.1007/s11356-021-17844-1-
Identifierhttps://link.springer.com/article/10.1007/s11356-021-17844-1-
Languageen-
Extent12 pagesen
TitleQuantification of trace transformation products of rocket fuel unsymmetrical dimethylhydrazine in sand using vacuum-assisted headspace solid-phase microextractionen
CreatorZhakupbekova Arayen
CreatorBaimatova Nassibaen
CreatorPsyllaki Eleftheriaen
CreatorΨυλλακη Ελευθεριαel
CreatorKenessov Bulaten
PublisherSpringeren
Content SummaryQuantification of unsymmetrical dimethylhydrazine transformation products in solid samples is an important stage in monitoring of environmental pollution caused by heavy rockets launches. The new method for simultaneous quantification of unsymmetrical dimethylhydrazine transformation products in sand samples using vacuum-assisted headspace solid-phase microextraction without addition of water followed by gas chromatography-mass spectrometry is proposed. Decreasing air evacuation time from 120 to 20 s at 23 °C resulted in increased responses of analytes by 25–46% and allowed obtaining similar responses as after evacuation at −30 °C. The best combination of responses of analytes and their relative standard deviations (RSDs) was achieved after air evacuation of a sample (m = 1.00 g) for 20 s at 23 °C, incubation for 30 min at 40 °C, and 30-min extraction at 40 °C by Carboxen/polydimethylsiloxane (Car/PDMS) fiber. The method was validated in terms of linearity (R2=0.9912–0.9938), limits of detection (0.035 to 3.6 ng g−1), limits of quantification (0.12–12 ng g−1), recovery (84–97% with RSDs 1–11%), repeatability (RSDs 3–9%), and reproducibility (RSDs 7–11%). It has a number of major advantages over existing methods based on headspace solid-phase microextraction—lower detection limits, better accuracy and precision at similar or lower cost of sample preparation. The developed method was successfully applied for studying losses of analytes from open vials with model sand spiked with unsymmetrical dimethylhydrazine transformation products. It can be recommended for analysis of trace concentrations of unsymmetrical dimethylhydrazine transformation products when studying their transformation, migration and distribution in contaminated sand.en
Type of ItemPeer-Reviewed Journal Publicationen
Type of ItemΔημοσίευση σε Περιοδικό με Κριτέςel
Licensehttp://creativecommons.org/licenses/by/4.0/en
Date of Item2024-02-22-
Date of Publication2022-
SubjectVacuum-assisted headspace solid-phase microextractionen
SubjectGas chromatography-mass spectrometryen
SubjectSoil analysisen
SubjectTransformation productsen
SubjectDimethylhydrazineen
SubjectRocket fuelen
Bibliographic CitationA. Zhakupbekova, N. Baimatova, E. Psillakis and B. Kenessov, “Quantification of trace transformation products of rocket fuel unsymmetrical dimethylhydrazine in sand using vacuum-assisted headspace solid-phase microextraction,” Environ. Sci. Pollut. Res., vol. 29, no. 22, pp. 33645–33656, May 2022, doi: 10.1007/s11356-021-17844-1.en

Services

Statistics