Study of human exposure and dose in hospital areas

Santa Vasiliki

Simple record


URIhttp://purl.tuc.gr/dl/dias/D33E7C05-C1A9-4182-BC08-44959BE6F784-
Identifierhttps://doi.org/10.26233/heallink.tuc.97679-
Languageel-
Extent2.4 megabytesen
Extent81 σελίδεςel
TitleΜελέτη της ανθρώπινης έκθεσης και δόσης σε νοσοκομειακούς χώρουςel
TitleStudy of human exposure and dose in hospital areasen
CreatorSanta Vasilikien
CreatorΣαντα Βασιλικηel
Contributor [Thesis Supervisor]Lazaridis Michailen
Contributor [Thesis Supervisor]Λαζαριδης Μιχαηλel
Contributor [Committee Member]Tsoutsos Theocharisen
Contributor [Committee Member]Τσουτσος Θεοχαρηςel
Contributor [Committee Member]Kopanakis Iliasen
Contributor [Committee Member]Κοπανακης Ηλιαςel
PublisherΠολυτεχνείο Κρήτηςel
PublisherTechnical University of Creteen
Academic UnitTechnical University of Crete::School of Chemical and Environmental Engineeringen
Academic UnitΠολυτεχνείο Κρήτης::Σχολή Χημικών Μηχανικών και Μηχανικών Περιβάλλοντοςel
Content SummaryΤις τελευταίες δεκαετίες η ρύπανση της ατμόσφαιρας ολοένα και αυξάνεται. Ο όρος ατμοσφαιρική ρύπανση χρησιμοποιείται για να περιγράψει την ύπαρξη χημικών ενώσεων στην ατμόσφαιρα σε συγκεντρώσεις που είναι επιβλαβείς για το περιβάλλον, την υγεία του ανθρώπου, καθώς και όλων τον έμβιων οργανισμών. Οι χημικές αυτές ενώσεις γενικά χαρακτηρίζονται ως ρύποι, καθώς μεταβάλλουν τα φυσικοχημικά χαρακτηριστικά της ατμόσφαιρας και έχουν αρνητικές επιπτώσεις στην ανθρώπινη υγεία σε παγκόσμιο επίπεδο. Η ατμοσφαιρική ρύπανση θεωρείται υπεύθυνη για διάφορα προβλήματα υγείας, κυρίως αναπνευστικά, για τη μείωση του προσδόκιμου ζωής αλλά και για πρόωρους θανάτους. Τα αιωρούμενα σωματίδια αποτελούν έναν κύριο ατμοσφαιρικό ρύπο. Λόγω του μικρού τους μεγέθους, είναι επικίνδυνα για την δημόσια υγεία, καθώς έχουν την ικανότητα να διεισδύουν στον ανθρώπινο οργανισμό και να αποτίθενται σε διάφορα μέρη του ανθρώπινου σώματος. Σκοπός της παρούσας διπλωματικής εργασίας είναι ο προσδιορισμός της σωματιδιακής ρύπανσης σε νοσοκομειακούς χώρους. Τρείς διαφορετικοί Νοσοκομειακοί χώροι (Γραφείο Νοσηλευτικής Υπηρεσίας, Παθολογικό Τμήμα και Έκτακτο Καρδιολογικό Τμήμα) μελετήθηκαν στην εργασία αυτή στο νοσοκομείο «Η Ελπίς» στην Αθήνα. Η μέση συγκέντρωση στο Γραφείο Νοσηλευτικής Υπηρεσίας μετρήθηκε ίση με 30,62 μg/m3 με τυπική απόκλιση ±12,45 μg/m3 , στο Παθολογικό Τμήμα ίση με 64,60 μg/m3 με τυπική απόκλιση ±54,06 μg/m3 και στο Έκτακτο Καρδιολογικό Τμήμα ίση με 24,43 μg/m3 με τυπική απόκλιση ±21,44 μg/m3. Στον εξωτερικό χώρο του Νοσοκομείου μετρήθηκε ίση με 31,50 μg/m3 με τυπική απόκλιση ±9,08 μg/m3. Με την βοήθεια του μοντέλου ExDoM2 υπολογίστηκε η εναποτιθέμενη δόση σε για μία ενήλικη γυναίκα στο χώρο του γραφείου κατά το ωράριο εργασίας της, για έναν ενήλικα άνδρα στο Παθολογικό τμήμα όταν αυτό εφημέρευε, για έναν ενήλικα άνδρα στο Παθολογικό τμήμα όταν αυτό δεν εφημέρευε, καθώς και στο Έκτακτο Καρδιολογικό τμήμα για έναν ενήλικα άνδρα, όταν εφημέρευε. Τέλος, με την βοήθεια του προγράμματος SPSS έγινε στατιστική ανάλυση των δεδομένων με σκοπό την σύγκριση των συγκεντρώσεων αιωρούμενων σωματιδίων στους διάφορους χώρους. Έγινε σύγκριση των συγκεντρώσεων των αιωρούμενων σωματιδίων για τις ώρες που είχε εφημερία το νοσοκομείο σε σχέση με τις ώρες που δεν είχε, σύγκριση για τους τρεις εσωτερικούς και τον εξωτερικό χώρο που πραγματοποιήθηκαν οι μετρήσεις, καθώς και σύγκριση των συγκεντρώσεων κατά την διάρκεια εργασίας του προσωπικού στο γραφείο σε σύγκριση με το χρονικό διάστημα που το γραφείο ήταν κλειστό. Τα αποτελέσματα της ανάλυσης έδειξαν ότι η μεγαλύτερη συγκέντρωση αιωρούμενων σωματιδίων (συγκριτικά με τους άλλους χώρους) ήταν στο Παθολογικό Τμήμα. Αυτό οφείλεται στην εικοσιτετράωρη παραμονή των ασθενών στο χώρο του Νοσοκομείου, το συχνό καθαρισμό και αερισμό του χώρου, στα συστήματα θέρμανσης, καθώς και την επίσκεψη συγγενών, γιατρών και του νοσηλευτικού προσωπικού στο χώρο.el
Content SummaryIn recent decades, air pollution has become increasingly noticeable. The term atmospheric pollution is used to describe the presence of various natural and chemical factors in the atmosphere, which are harmful of both the environment and human health, as well as all living organisms. These factors are generally referred to as pollutants, and they alter the natural characteristics of the atmosphere, with negative consequences for global public health. It is considered responsible for various respiratory and other health problems, as well as a reduction in life expectancy and premature deaths. One such pollutant is particulate matter, which, apart from its environmental impact, also has significant effects on the respiratory system and poses a danger to public health due to its ability to penetrate the human body and deposit in various parts of the human system. The purpose of this dissertation is to determine particulate pollution in three different hospital areas (Nursing Service Office, Pathology Department, and Emergency Cardiology Department). The average concentration in the Nursing Service Office was calculated to be 30.62 μg/m3 with a standard deviation of ±12.45 μg/m3, in the Pathology Department 64.60 μg/m3 with a standard deviation of ±54.06 μg/m3, and in the Emergency Cardiology Department 24.43 μg/m3 with a standard deviation of ±21.44 μg/m3. In the hospital's outdoor area, it was calculated to be 31.50 μg/m3 with a standard deviation of ±9.08 μg/m3. Using the ExDoM2 model, the deposited dose for an adult woman in the Nursing Service Office during her working hours, for an adult man in the Pathology Department when it was in operation, for an adult man in the Pathology Department when it was not in operation, and in the Emergency Cardiology Department when it was in operation were calculated. Finally, with the help of the SPSS program, a statistical analysis of the data was conducted to compare the concentrations of particulate matter in the various areas, studying three hypotheses. Specifically, the hypotheses concerned the comparison of particulate matter concentrations during the hospital's on-call hours compared to non-on-call hours, the comparison of concentrations for the three indoor and outdoor areas where measurements were taken, as well as the comparison of concentrations during working hours of the office compared to the time when the office is closed. The results of the program showed that the highest concentration of particulate matter (compared to other areas) was found in the Pathology Department. This is attributed to the 24 hours stay of patients in the hospital, frequent cleaning and ventilation of the space, heating systems, as well as visits from relatives, doctors, and nursing staff to the area.en
Type of ItemΔιπλωματική Εργασίαel
Type of ItemDiploma Worken
Licensehttp://creativecommons.org/licenses/by-nc/4.0/en
Date of Item2023-10-12-
Date of Publication2023-
SubjectΑιωρούμενα σωματίδιαel
Bibliographic CitationΒασιλική Σάντα, "Μελέτη της ανθρώπινης έκθεσης και δόσης σε νοσοκομειακούς χώρους", Διπλωματική Εργασία, Σχολή Χημικών Μηχανικών και Μηχανικών Περιβάλλοντος, Πολυτεχνείο Κρήτης, Χανιά, Ελλάς, 2023el
Bibliographic CitationVasiliki Santa, "Study of human exposure and dose in hospital areas", Diploma Work, School of Chemical and Environmental Engineering, Technical University of Crete, Chania, Greece, 2023en