URI | http://purl.tuc.gr/dl/dias/7B0FA8F8-7F2C-4ADF-9578-1A445728583F | - |
Αναγνωριστικό | https://doi.org/10.1016/j.neuroimage.2020.117353 | - |
Αναγνωριστικό | https://www.sciencedirect.com/science/article/pii/S1053811920308399?via%3Dihub | - |
Γλώσσα | en | - |
Μέγεθος | 14 pages | en |
Τίτλος | Inter-subject variability of skull conductivity and thickness in calibrated realistic head models | en |
Δημιουργός | Antonakakis Marios | en |
Δημιουργός | Αντωνακακης Μαριος | el |
Δημιουργός | Schrader Sophie | en |
Δημιουργός | Aydin Ümit | en |
Δημιουργός | Khan Asad | en |
Δημιουργός | Gross Joachim | en |
Δημιουργός | Zervakis Michail | en |
Δημιουργός | Ζερβακης Μιχαηλ | el |
Δημιουργός | Wolters Carsten H. | en |
Δημιουργός | Rampp, Stefan 1975- | en |
Εκδότης | Elsevier | en |
Περίληψη | Skull conductivity has a substantial influence on EEG and combined EEG and MEG source analysis as well as on optimized transcranial electric stimulation. To overcome the use of standard literature values, we propose a non-invasive two-level calibration procedure to estimate skull conductivity individually in a group study with twenty healthy adults. Our procedure requires only an additional run of combined somatosensory evoked potential and field data, which can be easily integrated in EEG/MEG experiments. The calibration procedure uses the P20/N20 topographies and subject-specific realistic head models from MRI. We investigate the inter-subject variability of skull conductivity and relate it to skull thickness, age and gender of the subjects, to the individual scalp P20/N20 surface distance between the P20 potential peak and the N20 potential trough as well as to the individual source depth of the P20/N20 source. We found a considerable inter-subject variability for (calibrated) skull conductivity (8.44 ± 4.84 mS/m) and skull thickness (5.97 ± 1.19 mm) with a statistically significant correlation between them (rho = 0.52). Age showed a statistically significant negative correlation with skull conductivity (rho = -0.5). Furthermore, P20/N20 surface distance and source depth showed large inter-subject variability of 12.08 ± 3.21 cm and 15.45 ± 4.54 mm, respectively, but there was no significant correlation between them. We also found no significant differences among gender subgroups for the investigated measures. It is thus important to take the inter-subject variability of skull conductivity and thickness into account by means of using subject-specific calibrated realistic head modeling. | en |
Τύπος | Peer-Reviewed Journal Publication | en |
Τύπος | Δημοσίευση σε Περιοδικό με Κριτές | el |
Άδεια Χρήσης | http://creativecommons.org/licenses/by/4.0/ | en |
Ημερομηνία | 2021-04-15 | - |
Ημερομηνία Δημοσίευσης | 2020 | - |
Θεματική Κατηγορία | Skull conductivity | en |
Θεματική Κατηγορία | Skull thickness | en |
Θεματική Κατηγορία | EEG/MEG source analysis | en |
Θεματική Κατηγορία | Transcranial electric stimulation | en |
Θεματική Κατηγορία | Calibrated realistic head model | en |
Θεματική Κατηγορία | Somatosensory evoked responses | en |
Βιβλιογραφική Αναφορά | M. Antonakakis, S. Schrader, Ü. Aydin, A. Khan, J. Gross, M. Zervakis, S. Rampp and C. H. Wolters, “Inter-subject variability of skull conductivity and thickness in calibrated realistic head models”, NeuroImage, vol. 223, Dec. 2020. doi: 10.1016/j.neuroimage.2020.117353 | en |