Institutional Repository [SANDBOX]
Technical University of Crete
EN  |  EL

Search

Browse

My Space

Combustion performance of sludge from a wastewater treatment plant in fluidized bed. Factorial modeling and optimization of emissions

Vamvouka Despoina, Alexandrakis Stylianos, Galetakis Michail

Simple record


URIhttp://purl.tuc.gr/dl/dias/03F2B7C3-5486-4263-BC35-BAC4B3DDAD89-
Identifierhttps://doi.org/10.3389/fenrg.2019.00043-
Identifierhttps://www.frontiersin.org/articles/10.3389/fenrg.2019.00043/full-
Languageen-
Extent10 pagesen
TitleCombustion performance of sludge from a wastewater treatment plant in fluidized bed. Factorial modeling and optimization of emissionsen
CreatorVamvouka Despoinaen
CreatorΒαμβουκα Δεσποιναel
CreatorAlexandrakis Stylianosen
CreatorΑλεξανδρακης Στυλιανοςel
CreatorGaletakis Michailen
CreatorΓαλετακης Μιχαηλel
PublisherFrontiers Mediaen
Content SummaryThe combustion performance of a bio-solid waste from a wastewater treatment plant was studied in terms of efficiency and gaseous emissions, by carrying out experiments in a bubbling fluid bed unit and was compared with that of an agricultural waste. The effects of excess air and fuel feeding rate were investigated and a factorial design and modeling was developed in order to provide optimal values of process variables for minimizing emissions. The results showed that sewage sludge fuel burned at a much lower temperature than the woody fuel. CO emissions were low, SO2 emissions from the agricultural waste negligible, while those of sewage sludge exceeded legislation limits when excess air was below 50%. An increase in excess air from 30 to 50%, or of fuel feeding rate from 0.48 to 0.6 kg/h, resulted in higher NOx emissions from the woody fuel, exceeding emission guidelines. Concerning SO2 and NOx emissions from sewage sludge fuel, the effect of feeding rate was the same, however that of excess air was opposite, reducing their levels in flue gases. Combustion efficiency for both fuels was high, between 98.5 and 99.6%. Factorial design analysis and modeling indicated that for the woody fuel the optimum emission performance was accomplished when the feeding rate was 0.48 kg/h and the excess air 30%. For the sewage sludge fuel the optimum combustion and emission performance was achieved when the feeding rate was 0.72 kg/h and the excess air 50%.en
Type of ItemPeer-Reviewed Journal Publicationen
Type of ItemΔημοσίευση σε Περιοδικό με Κριτέςel
Licensehttp://creativecommons.org/licenses/by/4.0/en
Date of Item2020-10-26-
Date of Publication2019-
SubjectCombustionen
SubjectEmissionsen
SubjectFluidized beden
SubjectModelingen
SubjectSewage sludgeen
Bibliographic CitationD. Vamvuka, S. Alexandrakis and M. Galetakis, "Combustion performance of sludge from a wastewater treatment plant in fluidized bed. Factorial modeling and optimization of emissions," Front. Energy Res., vol. 7, May 2019. doi: 10.3389/fenrg.2019.00043en

Available Files

Services

Statistics