Ιδρυματικό Αποθετήριο [SANDBOX]
Πολυτεχνείο Κρήτης
EN  |  EL

Αναζήτηση

Πλοήγηση

Ο Χώρος μου

Bioelectrochemical treatment of groundwater containing BTEX in a continuous-flow system: substrate interactions, microbial community analysis, and impact of sulfate as a co-contaminant

Palma Enza, Espinoza Tofalos Anna, Daghio Matteo, Franzetti Andrea, Tsiota Panagiota, Cruz Viggi Carolina, Aulenta Federico, Petrangeli Papini Marco

Απλή Εγγραφή


URIhttp://purl.tuc.gr/dl/dias/A0C2AF77-A939-4B6A-B168-40B56D1A2604-
Αναγνωριστικόhttps://doi.org/10.1016/j.nbt.2019.06.004-
Αναγνωριστικόhttps://www.sciencedirect.com/science/article/pii/S1871678418318880-
Γλώσσαen-
Μέγεθος8 pagesen
ΤίτλοςBioelectrochemical treatment of groundwater containing BTEX in a continuous-flow system: substrate interactions, microbial community analysis, and impact of sulfate as a co-contaminanten
ΔημιουργόςPalma Enzaen
ΔημιουργόςEspinoza Tofalos Annaen
ΔημιουργόςDaghio Matteoen
ΔημιουργόςFranzetti Andreaen
ΔημιουργόςTsiota Panagiotaen
ΔημιουργόςΤσιωτα Παναγιωταel
ΔημιουργόςCruz Viggi Carolinaen
ΔημιουργόςAulenta Federicoen
ΔημιουργόςPetrangeli Papini Marcoen
ΕκδότηςElsevieren
ΠερίληψηMicrobial electrochemical technologies (MET) are increasingly being considered for in situ remediation of contaminated groundwater. However, their application potential for the simultaneous treatment of complex mixtures of organic and inorganic contaminants, has been only marginally explored. Here we have analyzed the performance of the ‘bioelectric well’, a previously developed bioelectrochemical reactor configuration, in the treatment of benzene, toluene, ethyl-benzene and xylenes (BTEX) mixtures. Although to different extents, all BTEX were found to be degraded in the bioelectrochemical system, operated using a continuous-flow of groundwater at a hydraulic retention time of 8.8 h, with the graphite anode potentiostatically controlled at +0.200 V vs. the standard hydrogen electrode. In the case of toluene and ethyl-benzene, biodegradation was further confirmed by the GC–MS identification of fumarate-addition metabolites, previously shown to be involved in the activation of these contaminants under anaerobic conditions. Degradation rates were higher for toluene (31.3 ± 1.5 mg/L d) and lower for benzene (6.1 ± 0.3 mg/L d), ethyl-benzene (3.3 ± 0.1 mg/L d), and xylenes (4.5 ± 0.2 mg/L d). BTEX degradation was linked to electric current generation, with coulombic efficiencies falling in the range 53–69%, although methanogenesis also contributed to contaminant degradation. Remarkably, the system also allowed removal of sulfate simultaneously with toluene. Sulfate removal was likely driven by the hydrogen abiotically generated at the cathode. Taken as a whole, these findings highlight the remarkable potential of this innovative reactor configuration for application in a variety of contamination scenarios.en
ΤύποςPeer-Reviewed Journal Publicationen
ΤύποςΔημοσίευση σε Περιοδικό με Κριτέςel
Άδεια Χρήσηςhttp://creativecommons.org/licenses/by/4.0/en
Ημερομηνία2020-04-06-
Ημερομηνία Δημοσίευσης2019-
Θεματική ΚατηγορίαBTEXen
Θεματική ΚατηγορίαGeobacteren
Θεματική ΚατηγορίαMicrobial electrochemical technologiesen
Θεματική ΚατηγορίαSulfateen
Βιβλιογραφική ΑναφοράE. Palma, A. Espinoza Tofalos, M. Daghio, A. Franzetti, P. Tsiota, C. Cruz Viggi, M.P. Papini and F. Aulenta, "Bioelectrochemical treatment of groundwater containing BTEX in a continuous-flow system: substrate interactions, microbial community analysis, and impact of sulfate as a co-contaminant," New Biotechnol., vol. 53, pp. 41-48, Nov. 2019. doi: 10.1016/j.nbt.2019.06.004en

Υπηρεσίες

Στατιστικά