URI | http://purl.tuc.gr/dl/dias/B61974D9-0C71-48C0-A5E1-4D645F0576B7 | - |
Identifier | https://doi.org/10.1016/j.chroma.2018.04.048 | - |
Identifier | https://www.sciencedirect.com/science/article/pii/S0021967318304965 | - |
Language | en | - |
Extent | 7 pages | en |
Title | Determination of transformation products of unsymmetrical dimethylhydrazine in water using vacuum-assisted headspace solid-phase microextraction | en |
Creator | Orazbayeva Dina | en |
Creator | Kenessov Bulat | en |
Creator | Psyllaki Eleftheria | en |
Creator | Ψυλλακη Ελευθερια | el |
Creator | Nassyrova Dayana | en |
Creator | Bektassov Marat | en |
Publisher | Elsevier | en |
Content Summary | A new, sensitive and simple method based on vacuum-assisted headspace solid-phase microextraction (Vac-HSSPME) followed by gas chromatography-mass-spectrometry (GC–MS), is proposed for the quantification of rocket fuel unsymmetrical dimethylhydrazine (UDMH) transformation products in water samples. The target transformation products were: pyrazine, 1-methyl-1H-pyrazole, N-nitrosodimethylamine, N,N-dimethylformamide, 1-methyl-1Н-1,2,4-triazole, 1-methyl-imidazole and 1H-pyrazole. For these analytes and within shorter sampling times, Vac-HSSPME yielded detection limits (0.5–100 ng L−1) 3–10 times lower than those reported for regular HSSPME. Vac-HSSPME sampling for 30 min at 50 °C yielded the best combination of analyte responses and their standard deviations (<15%). 1-Formyl-2,2-dimethylhydrazine and formamide were discarded because of the poor precision and accuracy when using Vac-HSSPME. The recoveries for the rest of the analytes ranged between 80 and 119%. The modified Mininert valve and Thermogreen septum could be used for automated extraction as it ensured stable analyte signals even after long waiting times (>24 h). Finally, multiple Vac-HSSME proved to be an efficient tool for controlling the matrix effect and quantifying UDMH transformation products. | en |
Type of Item | Peer-Reviewed Journal Publication | en |
Type of Item | Δημοσίευση σε Περιοδικό με Κριτές | el |
License | http://creativecommons.org/licenses/by/4.0/ | en |
Date of Item | 2019-09-09 | - |
Date of Publication | 2018 | - |
Subject | Dimethylhydrazine | en |
Subject | Headspace solid-phase microextraction | en |
Subject | Multiple headspace solid-phase microextraction | en |
Subject | Transformation products | en |
Subject | Vacuum-assisted headspace solid-phase microextraction | en |
Subject | Water analysis | en |
Bibliographic Citation | D. Orazbayeva, B. Kenessov, E. Psillakis, D. Nassyrova and M. Bektassov, "Determination of transformation products of unsymmetrical dimethylhydrazine in water using vacuum-assisted headspace solid-phase microextraction," J. Chromatogr. A, vol. 1555, pp. 30-36, Jun. 2018. doi: 10.1016/j.chroma.2018.04.048 | en |