Institutional Repository [SANDBOX]
Technical University of Crete
EN  |  EL

Search

Browse

My Space

Particulate matter human exposure and deposit dose in indoor microenvironments of o University Campus

Kotsira Ioanna

Simple record


URIhttp://purl.tuc.gr/dl/dias/C4AD56F2-74C3-4A41-8427-9B5D4972BE35-
Identifierhttps://doi.org/10.26233/heallink.tuc.82387-
Languageel-
Extent95 σελίδεςel
TitleΠροσδιορισμός της ανθρώπινης έκθεσης και δόσης σε αιωρούμενα σωματίδια σε χώρους του Πολυτεχνείου Κρήτηςel
TitleParticulate matter human exposure and deposit dose in indoor microenvironments of o University Campusen
CreatorKotsira Ioannaen
CreatorΚοτσιρα Ιωανναel
Contributor [Committee Member]Kolokotsa Dionysiaen
Contributor [Committee Member]Κολοκοτσα Διονυσιαel
Contributor [Thesis Supervisor]Lazaridis Michailen
Contributor [Thesis Supervisor]Λαζαριδης Μιχαηλel
Contributor [Committee Member]Glytsos Theodorosen
Contributor [Committee Member]Γλυτσος Θεοδωροςel
PublisherΠολυτεχνείο Κρήτηςel
PublisherTechnical University of Creteen
Academic UnitTechnical University of Crete::School of Environmental Engineeringen
Academic UnitΠολυτεχνείο Κρήτης::Σχολή Μηχανικών Περιβάλλοντοςel
Content SummaryΤα αιωρούμενα σωματίδια (ΑΣ) είναι ένας σημαντικός ρύπος που συνδέεται με ποικίλες αρνητικές επιδράσεις στην ανθρώπινη υγεία, συμπεριλαμβανομένων αναπνευστικών προβλημάτων, καρδιαγγειακών επεισοδίων και σε κάποιες περιπτώσεις με αυξημένη θνησιμότητα. Οι επιπτώσεις στην ανθρώπινη υγεία εξαρτόνται από διάφορους παράγοντες, όπως η μορφολογία του ανθρώπινου αναπνευστικού συστήματος αλλά και τα χαρακτηριστικά των ΑΣ (το μέγεθος, το σχήμα, η πυκνότητα κ.α.). Σκοπός της διπλωματικής εργασίας ήταν η μελέτη της έκθεσης σε ΑΣ και ο υπολογισμός της εναποτιθέμενης δόσης για ένα ενήλικα άνδρα /γυναίκα σε διαφορετικά μικροπεριβάλλοντα εσωτερικών χώρων του Πολυτεχνείου Κρήτης. Επιπρόσθετα οι μεταβολές στις συγκεντρώσεις των ΑΣ χρησιμοποιήθηκαν για να εντοπιστούν πιθανές εσωτερικές πηγές στα μικροπεριβάλλοντα που μελετήθηκαν και να εκτιμηθεί η επίδραση του εξωτερικού περιβάλλοντος στο συνολικό σωματιδιακό φορτίο των εσωτερικών χώρων του Πολ. Κρήτης Επιλέχθηκαν τέσσερα μικροπεριβάλλοντα για τις μετρήσεις: μια αίθουσα, ένα εργαστήριο, ένα γραφείο και το κυλικείο της σχολής Μηχανικών Περιβάλλοντος. Ταυτόχρονα μετρήσεις διεξάχθηκαν στο εξωτερικό περιβάλλον, σε κοντινή απόσταση από τους χώους που μελετήθηκαν. Τα όργανα που χρησιμοποιήθηκαν για τις μετρήσεις ήταν δύο Dust Trak Aerosol monitors (Μοντέλα 8532 και 8530), δύο Optical Particle Sizer (OPS,μοντέλο 3330) και ένα P-Trak Ultrafine Particle Counter (TSI, model 8525). Ο υπολογισμός της εναποτιθέμενης δόσης έγινε με την χρήση του μοντέλου δοσιμετρίας ExDoM2 κατά την διάρκεια ενός υποθετικού σεναρίου δραστηριοτήτων ενός φοιτητή/φιτήτριας για 6 ώρες παραμονής στα παραπάνω μικροπεριβάλλοντα, εντός του χώρου του Πολυτεχνείου Κρήτης.el
Content SummaryParticulate Matter is a significant pollutant which is associated with a variety of adverse effects on human health, including respiratory promblems, cardiovascular events and in some cases increased mortality. These effects depend on various factors, such us the morphology of the human respiratory system and the characteristics of PM (size, shape density, etc). The aim of this study was to investigate the PM exposure and calculate the deposited dose for a typical adult male/female in different indoor microenvironments inside the campus of the Technical University of Crete. Furthermore, PM concentrations variations were used to identify possible indoor sources in the studied microenvironments and estimate the effect of the outdoor environment in the indoor PM load. Four indoor microenvironments were selected for the measurements: a classroom, a laboratory, an office and the canteen of the School of Environmental Engineering. Simultaneous measurements were conducted outdoors, in closed proximity to the studied microenvironments. The instrumentation used in the campaigns consisted of two Dust Trak Aerosol monitors (TSI, Models 8532 and 8530), two Optical Particle Sizers (TSI Model 3330) and one P-Trak Ultrafine Particle Counter (TSI, model8525). Calculations of the regional deposited dose were performed using the respiratory tract model ExDoM2 for a hypothetical scenario of activities of a male/female student during a typical 6 hours stay in the above studied microenvironments, inside the Campus of the Technical University of Crete.en
Type of ItemΔιπλωματική Εργασίαel
Type of ItemDiploma Worken
Licensehttp://creativecommons.org/licenses/by/4.0/en
Date of Item2019-07-05-
Date of Publication2019-
SubjectΕναποτιθέμενη δόσηel
SubjectDeposited doseen
SubjectIndoor microenvironmentsen
SubjectΜικροπεριβάλλοντα εσωτερικών χώρων el
SubjectExDoM2en
Subject PM exposureen
SubjectΑιωρούμενα σωματίδιαel
SubjectParticulate matteren
Bibliographic CitationΙωάννα Κότσιρα, "Προσδιορισμός της ανθρώπινης έκθεσης και δόσης σε αιωρούμενα σωματίδια σε χώρους του Πολυτεχνείου Κρήτης", Διπλωματική Εργασία, Σχολή Μηχανικών Περιβάλλοντος, Πολυτεχνείο Κρήτης, Χανιά, Ελλάς, 2019el
Bibliographic CitationIoanna Kotsira, "Particulate matter human exposure and deposit dose in indoor microenvironments of o University Campus", Diploma Work, School of Environmental Engineering, Technical University of Crete, Chania, Greece, 2019en

Available Files

Services

Statistics