URI | http://purl.tuc.gr/dl/dias/49CD3A93-CFB7-48AA-92E8-545ED5376821 | - |
Αναγνωριστικό | https://link.springer.com/article/10.1007%2Fs10453-016-9470-2 | - |
Αναγνωριστικό | https://doi.org/10.1007/s10453-016-9470-2 | - |
Γλώσσα | en | - |
Μέγεθος | 18 pages | en |
Τίτλος | Particle size distribution of cultivable airborne microbes and inhalable particulate matter in a wastewater treatment plant facility | en |
Δημιουργός | Κατσίβελα Ελευθερία | el |
Δημιουργός | Katsivela Eleftheria | en |
Δημιουργός | Λάτος Εμμανουήλ | el |
Δημιουργός | Latos Emmanouil | en |
Δημιουργός | Raisi Louisa | en |
Δημιουργός | Αλεξανδροπούλου Βικτώρια | el |
Δημιουργός | Aleksandropoulou Victoria | en |
Δημιουργός | Alexandropoulou Victoria | en |
Δημιουργός | Lazaridis Michalis | en |
Δημιουργός | Λαζαριδης Μιχαλης | el |
Εκδότης | SpringerOpen | en |
Περίληψη | A field study was performed to identify the size distribution characteristics of viable, cultivable airborne microorganisms (heterotrophic bacteria, fungi, and total coliforms) at a municipal wastewater treatment facility, and their association with inhalable particulate matter (PM1, PM2.5, and PM10), as well as hydrogen sulfide concentrations and ambient meteorological parameters. The highest concentrations of cultivable, airborne heterotrophic bacteria, total coliforms, mass and number concentration of particulate matter, as well as hydrogen sulfide were observed at the aerated grit removal chambers at the pretreatment stage (3 to 2030 times higher than the values of the background ambient air). In contrast, the mean concentrations of cultivable, airborne mesophilic fungi at the aerated grit chambers were 0.6 time lower than the background site, where fungi presented the most abundant taxonomic group in the ambient air. Although the highest concentrations of the airborne fungi were determined at aerodynamic diameters between 2.1 and 3.3 μm, a nearly equal distribution of the mean concentrations of the cultivable, airborne heterotrophic bacteria were observed in the six different size fractions at the primary settling tanks and in the ambient air. Interestingly, their size distribution profiles at the aerated grit chambers were different and showed a maximum aerodynamic diameter at the size range from 3.3 to 4.7 μm, similar to that of the cultivable, airborne total coliforms. In general, low positive or no significant linear relationships could be found between the cultivable airborne heterotrophic bacteria, total coliforms, or fungi at the two wastewater treatment stages and the ambient background microbial community. | en |
Τύπος | Peer-Reviewed Journal Publication | en |
Τύπος | Δημοσίευση σε Περιοδικό με Κριτές | el |
Άδεια Χρήσης | http://creativecommons.org/licenses/by/4.0/ | en |
Ημερομηνία | 2018-03-29 | - |
Ημερομηνία Δημοσίευσης | 2017 | - |
Θεματική Κατηγορία | Bacteria | en |
Θεματική Κατηγορία | Bioaerosols | en |
Θεματική Κατηγορία | Fungi | en |
Θεματική Κατηγορία | Particle size distribution | en |
Θεματική Κατηγορία | Particulate matter | en |
Θεματική Κατηγορία | Wastewater | en |
Βιβλιογραφική Αναφορά | E. Katsivela, E. Latos, L. Raisi, V. Aleksandropoulou and M. Lazaridis, "Particle size distribution of cultivable airborne microbes and inhalable particulate matter in a wastewater treatment plant facility," Aerobiologia, vol. 33, no. 3, pp. 297-314, Sept. 2017. doi : 10.1007/s10453-016-9470-2 | en |