Institutional Repository [SANDBOX]
Technical University of Crete
EN  |  EL

Search

Browse

My Space

Electrochemical oxidation of stabilized landfill leachate on DSA electrodes

Turro Elisabetta , Giannis Apostolos, Cossu, R, Gidarakos Evaggelos, Mantzavinos Dionysis, Katsaounis Alexandros

Full record


URI: http://purl.tuc.gr/dl/dias/065611DA-0B4D-4ADC-9709-A50A8C068A14
Year 2011
Type of Item Peer-Reviewed Journal Publication
License
Details
Bibliographic Citation E. Turro, A. Giannis, R. Cossu, E. Gidarakos, D. Mantzavinos and A. Katsaounis, "Electrochemical oxidation of stabilized landfill leachate on DSA electrodes", J. Hazard. Mater., vol. 190, no. 1-3, pp. 460-465, Jun. 2011. doi:10.1016/j.jhazmat.2011.03.085 https://doi.org/10.1016/j.jhazmat.2011.03.085
Appears in Collections

Summary

The electrochemical oxidation of stabilized landfill leachate with 2960 mg L(-1) chemical oxygen demand (COD) over a Ti/IrO(2)-RuO(2) anode was investigated in the presence of HClO(4) as the supporting electrolyte. Emphasis was given on the effect of electrolysis time (up to 240 min) and temperature (30, 60 and 80°C), current density (8, 16 and 32 mA cm(-2)), initial effluent's pH (0.25, 3, 5 and 6), HClO(4) concentration (0.25 and 1M) and the addition of NaCl (20 and 100mM) or Na(2)SO(4) (20mM) as source of extra electrogenerated oxidants on performance; the latter was evaluated regarding COD, total carbon (TC), total phenols (TPh) and color removal. Moreover, the anode was studied by scanning electron microscopy and cyclic voltammetry. The main parameters affecting the process were the effluent's pH and the addition of salts. Treatment for 240 min at 32 mA cm(-2) current density, 80°C and the pH adjusted from its inherent value of 0.25 (i.e. after the addition of HClO(4)) to 3 yielded 90% COD, 65% TC and complete color and TPh removal at an electricity consumption of 35 kWh kg(-1) COD removed. Comparable performance (i.e. 75% COD reduction) could be achieved without pH adjustment but with the addition of 100mM NaCl consuming 20 kWh kg(-1) COD removed.

Services