Το έργο με τίτλο Strengthening of masonry using metal reinforcement. A parametric numerical investigation από τον/τους δημιουργό/ούς Stavroulaki Maria, G. Bartoli, M. Betti, Stavroulakis Georgios διατίθεται με την άδεια Creative Commons Αναφορά Δημιουργού 4.0 Διεθνές
Βιβλιογραφική Αναφορά
M.E. Stavroulaki,G. Bartoli,M. Betti,G. E. Stavroulakis ,"Strengthening of masonry using metal reinforcement. A parametric numerical investigation ," in 1st International Conference on Protection of Historical Buildings by Reversible Mixed Technologies, 2009 ,pp.1187-1193.
Metal rods and prestressed cables can be used for the strengthening of masonry structures andmonuments. These techniques are partially reversible and introduce minimal changes in the characteristics andthe structural system. Therefore they are practical and economical alternatives to more traditional strengtheningmethods. The research to date has mainly focused on component behavior and only few results about theeffectiveness of post-tensioning retrofits on overall structure response has been published. In this paper a numberof numerical models and extensive parametric investigation was done in order to study the effectiveness of thepreviously mentioned technique, by analyzing the response of a masonry tower as a case study. Both staticand dynamic analyses considering base excitation loads were performed. The effectiveness of the prestressingdepends on the location of the cables, the material and the geometry of the structure. Prestressing must beaccompanied with local reinforcement in order to reduce excessive deformations and damages