Effects of varying levels of background noise on room acoustic parameters, measured with ESS and MLS methods

Papadakis Nikolaos, Antoniadou Smaro, Stavroulakis Georgios

Απλή Εγγραφή


URIhttp://purl.tuc.gr/dl/dias/858EDCE2-7F06-4831-B39D-E1FEC8DAC27C-
Αναγνωριστικόhttps://doi.org/10.3390/acoustics5020034-
Αναγνωριστικόhttps://www.mdpi.com/2624-599X/5/2/34-
Γλώσσαen-
Μέγεθος12 pagesen
ΤίτλοςEffects of varying levels of background noise on room acoustic parameters, measured with ESS and MLS methodsen
ΔημιουργόςPapadakis Nikolaosen
ΔημιουργόςΠαπαδακης Νικολαοςel
ΔημιουργόςAntoniadou Smaroen
ΔημιουργόςStavroulakis Georgiosen
ΔημιουργόςΣταυρουλακης Γεωργιοςel
ΕκδότηςMDPIen
ΠερίληψηTypically, background noise of different types and levels is present during the measurement of the impulse response in spaces. The two methods that are, in practice, most frequently used in the measurement of the impulse response, are the exponential sine sweep (ESS), and the maximum length sequence (MLS). This study’s objective was to estimate the impact of background noise (white noise, tonal noise) on the acoustic parameters (T30, EDT, C80, and D50) for ESS and MLS measurements, by introducing artificial background noise, employing an external sound source. For this purpose, measurements were performed with varying levels of external noise (in steps of 2 dB), and the effect was assessed, using the relative error compared to measurements without artificial background noise. According to the findings for white noise (as background noise), in the case of T30 and EDT, the difference between the two methods, as well as the relative error, for the initial levels of added background noise, was small. However, for higher levels of added background noise, there was a sharp increase in the relative error, which was greater for the ESS method, both for T30 and EDT. Regarding C80 and D50, while initially the differences between the ESS and MLS methods were small, cumulatively, as the background noise increased, the relative error increased for both methods, with the ESS method showing the largest error. In the case of tonal noise (as background noise), the results were consistent with those observed in the case of white noise. The study’s findings contribute to a better understanding of the ESS and MLS methods, and suggest the expected relative error of acoustic parameters when various types and levels of background noise are present. Additionally, the study suggests, based on background noise and level, the optimum method to conduct impulse response measurements.en
ΤύποςPeer-Reviewed Journal Publicationen
ΤύποςΔημοσίευση σε Περιοδικό με Κριτέςel
Άδεια Χρήσηςhttp://creativecommons.org/licenses/by/4.0/en
Ημερομηνία2025-04-14-
Ημερομηνία Δημοσίευσης2023-
Θεματική ΚατηγορίαAcoustic measurementen
Θεματική ΚατηγορίαExponential sine sweepen
Θεματική ΚατηγορίαMaximum length sequenceen
Θεματική ΚατηγορίαRoom acousticsen
Θεματική ΚατηγορίαISO 3382-1:2009en
Θεματική ΚατηγορίαImpulse responseen
Θεματική ΚατηγορίαMLSen
Θεματική ΚατηγορίαESSen
Θεματική ΚατηγορίαSwept-sineen
Θεματική ΚατηγορίαArchitectural acousticsen
Βιβλιογραφική ΑναφοράN. M. Papadakis, S. Antoniadou and G. E. Stavroulakis, “Effects of varying levels of background noise on room acoustic parameters, measured with ESS and MLS methods,” Acoustics, vol. 5, no. 2, pp. 563–574, June 2023, doi: 10.3390/acoustics5020034.en