Losses analysis of direct drive PM generators suffering from demagnetization

Goh S. Y., Fawzal Ahmad Syahid, Rasid Syidy Ab, Mueller Markus, Gyftakis Konstantinos

Full record


URI: http://purl.tuc.gr/dl/dias/7F3DD7B0-AC3E-47C5-855A-EADD54FAAE00
Year 2022
Type of Item Conference Full Paper
License
Details
Bibliographic Citation S. Goh, A. S. Fawzal, S. Rasid, M. Mueller and K. N. Gyftakis, "Losses analysis of direct drive PM generators suffering from demagnetization," in Proceedings of the 2022 International Conference on Electrical Machines (ICEM 2022), Valencia, Spain, 2022, pp. 1737-1743, doi: 10.1109/ICEM51905.2022.9910816. https://doi.org/10.1109/ICEM51905.2022.9910816
Appears in Collections

Summary

Direct drive PM generators are critical machines and gain ground in the field of renewables, especially in remote applications. It is therefore important to guarantee their reliability and long uninterrupted operation. One faulty condition that may propagate over time, if undetected, is the demagnetization one. This paper studies the impact of partial demagnetization on the electromagnetic and thermal performance of PM generators. More specifically, the fault will create a magnetic imbalance leading to the creation of circulating currents in the stator coils. The circulating currents will in turn increase the machines’ losses and drop of efficiency and consequently increase the severity of the fault. Finally, the paper offers a fault severity analysis and relates it with the electromagnetic and thermal stress of the faulty PM machines.